B57560G560 is Glass-Encapsulated Sensors manufactured by EPCOS.
Features
Glass-encapsulated, heat-resistive and highly stable For temperature measurement up to 300 °C Fast response Leads: dumet wires (copper-clad Fe Ni)
ø0,3
67±5
TNT0281-E
Options Leads: nickel-plated wires Delivery mode Bulk Climatic category (IEC 60068-1) Max. power at 25 °C Resistance tolerance .. Rated temperature Dissipation factor (in air) Thermal cooling time constant (in air) Heat capacity 55/300/56 50 ± 1 %, ± 3 %, ± 5 % 25 approx. 1,3 approx. 15 approx. 20
Dimensions in mm
P25 ∆R N/R N TN δth τc Cth m W
°C m W/K s m J/K
R 25
No. of R/T characteristic 2k 5k 8401 8402 8407 8415 8415 8403 8404 8405 8406
B 25/85 K 3420 3480 3480 3992 3992 3992 4066 4240 4557
B 0/100 K 3390 ± 1 % 3450 ± 1 % 3450 ± 1 % 3970 ± 1 % 3970 ± 1 % 3970 ± 1 % 4036 ± 1 % 4537 ± 1 %1) 5133 ± 2 %2)
B 25/100 K 3436 3497 3497 4006 4006 4006 4085 4264 4581
Ordering code
Ω
B57560G0202+ B57560G0502+ B57560G0103+ B57560G0203+ B57560G0303+ B57560G0503+ B57560G0104+ B57560G0234+ B57560G0145+
10 k 20 k 30 k 50 k 100 k 230 k 1400 k
+: F000 for ∆RN/R N = ± 1 %; H000 for ∆RN/R N = ± 3 %; J000 for ∆RN/R N = ± 5 %;
1) B100/200 2) B200/300
F002 for ∆RN/R N = ± 1 % for nickel-plated wires H002 for ∆RN/R N = ± 3 % for nickel-plated wires J002 for ∆RN/R N = ± 5 % for nickel-plated wires
104 05/02
Temperature Measurement Glass-Encapsulated Sensors
Reliability data Test Storage in dry heat Standard IEC 60068-2-2 Test conditions Storage at upper category temperature T: 300 °C t: 1000 h Temperature of air: 85 °C Relative humidity of air: 85 % Duration: 56 days
B57560 G 560
∆R 25/R25 (typical)
<3%
Remarks No visible damage
Storage in damp heat, steady state Rapid temperature cycling
IEC 60068-2-3 IEC 60068-2-14
<2%
No visible damage No visible damage
Lower test temperature:
- 55 °C < 2 % Upper test temperature: 200 °C Number of cycles: 1000
105 05/02