HRS1K-S-DC24V
HRS1KH
Relay
1.COIL DATA
1-1.Nominal Voltage 1-2.Coil Resistance 1-3.Operate Voltage 1-4.Release Voltage 1-5.Coil Power 3,5,6,9,12,24VDC Refer to Coil Data Chart Refer to Coil Data Chart Refer to Coil Data Chart 200m W 360m W
2.CONTACT DATA
2-1.Contact Form 2-2.Contact Material 2-3.Contact Rating 2-4.Max.Switching Voltage 2-5.Max.Switching Current 2-6.Max.Switching Power 2-7.Min.Switching Load 2-8.Contact Resistance 2-9.Life Electrical Mechanical 100,000 operations at nominal load 10,000,000 operations C-1 form C Au Ag overlay,Ag Alloy 1A 120VAC/24VDC 220VAC/30VDC 2A 120VA,30W 5VDC,10m A Max.50m 6VDC 0.1A
3.GENERAL DATA
3-1. Insulation Resistance 3-2. Dielectric Strength
Min.100M
500VDC
750VAC,1min between open contacts NIL:1,500VAC,1min between coil and contacts E:2,500VAC,1min between coil and contacts
3-3. Operate Time 3-4. Release Time 3-5. Operate Temperature 3-6. Shock Resistance
Max.5ms Max.5ms -25 ~+70 C 1,000m/s 2 100m/s 2 10 -55Hz,1.5mm double amplitude 10...