NESSCAP
Features
Cylindrical cell Radial lead terminals
60+2 MAX 6±1
(+) Positive Terminal Blank Terminal
Ø35+1MAX
Safety Vent Sleev( PVC)
.
(-) Negative Terminal
Dimensions in mm (not to scale) CAUTION Use the blank terminals for mechanical support only The blank terminals must not be connected any copper on PCB
..
Be sure to electrically isolate from negative the positive terminals.
- Specifications
400 Farads -10% / +10% 2.7 V 2.85 V 81 A > 202 A 1,458J (0.405Wh) 6.23 Wh/kg 6.98 Wh/l 5.34 k W/kg 5.99 k W/l 3.2 mΩ 4.2 mΩ φ 35 x l 60 mm 58 ml 65 g -40 ~ 60 °C -40 ~ 70 °C 1.0 m A 10 years 500,000 cycles
(6) C < 30% and ESR < 2 times of initially measured value, respectively and LC < specified value (7) 1 cycle: charging to VR for 20s, constant voltage charging for 10s, discharging to 1/2VR for 20s, rest for 10s -1(5) C < 20% and ESR < 2 times of initially measured value at 25o C, respectively (1) Discharging with constant current
(at matched load)
Rated Capacitance, C (DCC(1), 25o C)...