VRE101 Overview
VRE100 Series Precision Voltage References provide ultrastable +10.000V (VRE100), 10.000V (VRE101) and ±10.000V (VRE102) outputs with ±0.5 mV initial accuracy and temperature coefficient as low as 0.5 ppm/°C over the full military temperature range. This improvement in accuracy is made possible by a unique, proprietary multipoint laser pensation technique developed by Thaler Corporation. Significant improvements...
VRE101 Key Features
- VERY HIGH ACCURACY: 10.000 V OUTPUT ±0.5 mV
- EXTREMELY LOW DRIFT: 0.5 ppm/°C 55°C to +125°C
- LOW WARM-UP DRIFT: 1.0 ppm Typ
- EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ
- EXCELLENT LINE REGULATION: 3 ppm/V Typ
- HERMETIC 14-PIN CERAMIC DIP
- MILITARY PROCESSING OPTION
- PIN & FUNCTION PATIBLE WITH AD2700, AD2710 Series