AD7216N2L
Key Features
- Class II
- Universal AC input
- Fully regulated output
- Overvoltage and short circuit protection
- Constant voltage
- High efficiency
- IEC320 AC receptacle, 2 pin (type C8)
- (CISPR 22 Class B)
- AC Input fuse
- Complies with Blue Angel requirement Input range: Frequency: Input current: Efficiency: EMI/RFI: Safety ground leakage current: 90-264 Vac (wide range) 47-63 Hz 2 A maximum 85% typical FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class B 0.5 mA maximum@ 50/60 Hz, 264 Vac input Output Maximum Power (Po): Hold-up time: 72 W 10 ms. minimum at full load @ 120 Vac Short current protection: Auto recover Thermal protection: Internally protected; output will latch off Cable/connector: Overvoltage protection: DC cable length 2.1 mm center plug, right angle DC plug center +v DC plug outer -v 20 - 23 V; Lataching type, recycle ac to reset Environmental Specifications Operating temperature: Storage temperature: Electromagnetic susceptibility: Humidity: +5° to +40°C ambient -10°C to +70°C Designed to meet EN61000-4-2, -4, level 2; EN61000-4-5, Level 3 Operating; non-condensing 5% to 90% RH Safety UL: CuL: PSE: CB: UL 60950-1 60950-1 Denan Certificate and report Embedded Power for Business-Critical Continuity