AED13B50-L
Features
- Intermediate Bus Converter for Front End (DPA) Distributed Power Architecture application
- High efficiency (95% Typical)
- Industry standard package 16th Brick 0.90” x 1.30”
- High capacitive load limit on start-up ..
- Output Enable Pin
- Undervoltage lockout
- Over Temperature Protection
- Meets Basic Insulation
- EU directive 2002/95/EC pliant for Ro HS
Input range: Efficiency: Over Voltage Protection: Input UVLO:
8 V to 60 V 3 95%@ 12 V (typical) 67 V typical 33 V to 38 V 13 A max 8.7 V to 15 V 180 m V (typical) Auto-restart 165 k Hz TTL patible (positive or negative enable logic) 2000 Vdc max
Output
Output current: Output Voltage over line, load and temperature: Noise/ripple1: Over current limit: Switching frequency:
Over temperature protection: 110 °C minimum (autorecovery)
Control
Enable: Isolation Voltage: Input to Output:
Environmental Specifications
Safety
- UL, c UL: 60950
- TUV: EN60950 Operating ambient temperature range:...