Emerson AEO20A48N-L
DC-DC / Industry Standard Isolated Eighth Brick
ELECTRICAL SPECIFICATIONS
SpecialFEATURES
Input Input range: Input surge: Input UVLO: Efficiency2: 36 - 75VDC 100V / 100ms 33-36 V (UVLO ON) 31-31 V (UVLO OFF) 93% @ 5V (typical) <0.1% vo (typical) Up to 25A for Vo < 1.8V 20mVPK-PK (typical for Vo < 2.5V) 2% typical deviation (50% to 75% Step Load) <100us settling time (typ) 130% Vo typ (autorecovery) 130% Io,max typ (autorecovery)● 2.3” x 0.9” Industry Standard 8th brick outline
● Baseplate or Openframe construction
● Low Ripple and Noise
● Regulation to zero load
● High Capacitive load start-up
● Fixed Frequency Switching for EMI predictability
● Industry Standard features: Input UVLO with hysteresis, Enable, OVP, OCP, OTP, Output, VoltageTrim, Differential Remote Sense
● Meets Basic Insulation
● EU Directive 2002/95/EC compliant for RoHS Output Line / Load Regulation: Load Current: Noise / Ripple1: Transient Response: Over Voltage Protection: Over Current Protection: Over Temperature Protection: 115°C average PCB temperature (aut...