Datasheet4U Logo Datasheet4U.com

AEQ75Y48N-3L - DC-DC / Industry Standard Isolated Quarter Brick

This page provides the datasheet information for the AEQ75Y48N-3L, a member of the AEQ75Y48N-3L_aeq75_ds_1191276445 DC-DC / Industry Standard Isolated Quarter Brick family.

Features

  • High Efficiency Baseplate construction Industry standard package 1.45" x 2.30" Redundant output power pins Startup and stable operation at high capacitive load Remote sense compensation Regulation to zero load Fixed frequency switching Basic insulation EU Directive 2002/95/EC Compliant for RoHS Overvoltage Protection Current Limit Switching Frequency Control Voltage Adjust Enable 90 to 110% Vo TT.

📥 Download Datasheet

Datasheet preview – AEQ75Y48N-3L

Datasheet Details

Part number AEQ75Y48N-3L
Manufacturer Emerson
File Size 164.47 KB
Description DC-DC / Industry Standard Isolated Quarter Brick
Datasheet download datasheet AEQ75Y48N-3L Datasheet
Additional preview pages of the AEQ75Y48N-3L datasheet.
Other Datasheets by Emerson

Full PDF Text Transcription

Click to expand full text
Astec Industry Standard 75 Amps AEQ75Y48 High Efficiency Quarter Brick Total Power: Input Voltages: No. of Outputs: 135W 48V Single Electrical Specs Input Input Range Input Surge Efficiency 36 to 75 VDC 100V /100ms 89% typical Output Output Current Line/Load Regulation Noise/Ripple Remote sense Transient Response 75A max <0.15%Vo typical 25mV typical Up to 10% of Vo 4% deviation typical 50% to 75% Load change 0.1A/µs Slew Rate 100µs recovery 120% Vo (autorecovery) 110% Io (autorecovery) 500kHz Special Features • • • • • • • • • • High Efficiency Baseplate construction Industry standard package 1.45" x 2.
Published: |