Features

  • High efficiency.
  • Industry standard package 1.45" x 2.30".
  • Baseplate (AEQ) or Openframe (ALQ) construction.
  • High capacitive load limit on start-up.
  • Remote sense compensation.
  • Regulation to zero load.
  • Fixed frequency switching.
  • Basic insulation.
  • EU Directive 2002/95/EC Compliant for RoHS Overvoltage Protection Current Limit Switching Frequency Control Voltage Adjust Enable 90 to 110% Vo TTL compatible (Positive or N.

📥 Download Datasheet

Datasheet preview – ALQ60Y48

Datasheet Details

Part number ALQ60Y48
Manufacturer Emerson
File Size 189.14 KB
Description DC-DC / Industry Standard Isolated Quarter Brick
Datasheet download datasheet ALQ60Y48 Datasheet
Additional preview pages of the ALQ60Y48 datasheet.
Other Datasheets by Emerson

Full PDF Text Transcription

Click to expand full text
Astec Industry Standard 60 Amps AEQ/ALQ60 High Efficiency Quarter Brick Total Power: Input Voltages: No. of Outputs: 108W 48V Single Electrical Specs Input Input Range Input Surge Efficiency 36 to 75 VDC 100V /100ms > 90%@1.8V (50% to 100% load) Output Line Regulation Load Regulation Noise/Ripple Remote sense Transient Response ±0.2%Vo ±0.2%Vo 25mV typ Up to 10% of Vo 4% deviation typical 50% to 75% Load change 0.1A/µs Slew Rate 150µs recovery 125% Vo 115% nominal output 480kHz Special Features • High efficiency • Industry standard package 1.45" x 2.