ATCR250-48D12-03J
ATCR250-48D12-03J is Embedded Power manufactured by Emerson.
ss w
.Data Sheet.co.kr
Embedded Power for Business-Critical Continuity
Rev. 05.06.11_112 ATCR250 Series 1 of 3
Total Power: 250 Watts Input Voltage: -48 VDC Output: 12 V Intermediate Bus 3.3 V Management Bus
Electrical Specifications
Input
Input ra nge: Transient: External Input Capacitance: 36 V to -72 VDC -100 VDC (< 1 ms) 82u F max 11 A typ < 2ms -36 < VIN -77.5 ≤ VIN < 72 VDC 89% @ 250W 12 V Intermediate Bus 12.2 V 11.4
- 12.6 V 0
- 20.83 A 118% lo, max (typ) Shutdown/Autorecovery 50 m Vp-p Vo > 13.4 VDC NA 1000 u F min 3.3 V Management Bus 3.32V 3.20
- 3.40 V 0
- 4.5 A 130% lo, max (typ) 40 m Vp-p Vo > 3.6 VDC (typ) Vo < 3.0 VDC (typ) 100 u F min
Special Features
Inrush Current: Inrush Duration: Undervoltage Lockout: Overvoltage Lockout: Efficiency:
- Optimized footprint for high density ATCA applications
- Accepts inputs from -48 V and B Feeds
- CISPR Class A EMI
- Adjustable Hold Up Voltage from 50 to 80 VDC
- I2C serial bus interface for monitoring and reporting
- Programmable alarm thresholds via I2C bus
- Hardware alarms via opto isolators for loss of A or B Feeds
- prehensive protection circuitry
- current, voltage and temperature
- EU directive 2002/95/EC pliant for Ro HS
Output
Nominal Setpoint: Total Regulation Band1: Output Current: Current Limit: Short Circuit: Ripple and Noise2: Overvoltage: Undervoltage: External Output Capacitance:
Control/Monitoring
ON/OFF+ and ON/OFF-: I2C Serial Bus Interface: Remote activation of Module. See ATCR250 Application Note For digital monitoring (Vout, Vin, Temp, lin) referenced to secondary side
Isolation Characteristic