BXA3-24S05J
BXA3-24S05J is DC-DC / Low Power Isolated Industrial manufactured by Emerson.
- Part of the BXA3-24S05J_bxa3_ds_1193850976 comparator family.
- Part of the BXA3-24S05J_bxa3_ds_1193850976 comparator family.
Features
- 3 Watts in DIL Package
- 9 models including 3.3 Vdc output
- Wide input ranges 9 Vdc to 18 Vdc, 18 Vdc to 36 Vdc, 36 Vdc to 75 Vdc
- EN55022 conducted emissions level A (optional)
- Continuous short circuit protection
- Operating temperature range -25 °C to +105 °C
- Input voltage range to ETS300-132-2
- UL, VDE and CSA safety approvals
- Available Ro HS pliant
- 2 year warranty
The BXA3 Series of dc-dc converters is designed to offer the optimum cost/benefit power solution for a wide variety of applications including public and private telemunications, industrial systems and process and test equipment. The series consists of 9 models with input voltages of 9 Vdc to 18Vdc, 18 Vdc to 36 Vdc and 36 Vdc to 75 Vdc, and offers standard output voltages of 3.3 V, 5 V, 12 V and 15 V in single and dual output configurations. Continuous short-circuit protection, overvoltage protection, 60 m V output ripple and EN55022 level A conducted noise pliance minimize design-in time, cost and eliminate the need for external ponents.
Safety
VDE0805/EN60950/IEC950 File No. 10401-3336-0098 Licence No. 5856 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C
Embedded Power for Business-Critical Continuity
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Rev.03.07.07 bxa3 2 of 4
OUTPUT SPECIFICATIONS Voltage accuracy Line regulation Load regulation Ripple and noise (5 Hz to 20 MHz) LL to HL, all outputs Full load to no load +5 V output All others Temperature coefficient Over voltage protection Short circuit protection INPUT SPECIFICATIONS Input voltage range 12 Vdc 24 Vdc 48 Vdc Suffix ‘-F’ (See Note 5) (See Note 7) Output remains within specification 9-18 Vdc 18-36 Vdc 36-75 Vdc Pi type Yes 5 V/ms Clamp diode ±1.0% ±2.5% ±2.5% 60 m V pk-pk, max., 15 m V rms 100 m V pk-pk, max., 15 m V rms ±0.02%/°C, max. 135% Vout Continuous automatic recovery
EMC CHARACTERISTICS Conducted emissions EN55022, FCC part 15 Suffix...