LPT104-M
Features
- -
- -
- -
- -
- -
- -
- Medical and ITE safeties Active power factor correction 2” x 4” footprint Less than 1U high EN61000-3-2 pliant Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection LPX50 enclosure kit available
Electrical Specifications
Input
Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Safety ground leakage current: 90
- 264 Vac; 127
- 300 Vdc 47
- 63 Hz 50 A max., cold start @ 25 °C 82% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 275 µA @ 50/60 Hz, 264 Vac input
Output
Maximum power: 80 W for convection; 130 W with 200 LFM forced air Adjustment range: All outputs adjustable