• Part: NLP250R-96S24J
  • Description: AC-DC / 136W - 260W
  • Manufacturer: Emerson
  • Size: 596.64 KB
Download NLP250R-96S24J Datasheet PDF
Emerson
NLP250R-96S24J
NLP250R-96S24J is AC-DC / 136W - 260W manufactured by Emerson.
- Part of the NLP250R-96S24J_nlp250_series_ds_1193850838 comparator family.
Embedded Power for Business-Critical Continuity NLP250 Series Single Output Rev.10.1.09_1 NLP250 Series of 4 Total Power: 250 W Input Voltage: 85 - 264 Vac # of Outputs: Single Special Features - Active PFC and EN61000-3-2 pliant - 250 W on main channel with forced air - Low profile fits 1U applications - U-Channel for maximum thermal performance - Optional cover (CJ suffix) - 5 V standby output - 12 V fan output - Integrated ORing diode - Active current sharing - Integrated control and monitoring Features - Overcurrent, overvoltage and overtemperature protection - pliance to EN55022-B conducted noise standard - Ro HS pliant - 2 year warranty Electrical Specifications Input Input voltage range: Input frequency range: Input surge current: Safety ground leakage current: Input current: Input fuse: 264 Vac (cold start) 264 Vac, 50 Hz 120 Vac @ 250 W 230 Vac @ 250 W UL/IEC127 200 LFM forced air 250 LFM with cover Main output Main output Auxiliary outputs @ 120 Vac Input Main output 50 - 100% Step at 0.5 A/µs Main output Cyclic operation Singles 5 Vsb 12 V (fan) Universal input 85 - 264 Vac 47 - 63 Hz 40 A max. 1 m A 2.78 A rms 1.36 A rms T6.3 AH, 250 Vac 250 watts ± 5% ± 2.0% ± 5.0% 2.0 s max. 5.0% or 250 m V max. dev., 1 ms max recovery to 1% ±0.02%/°C 115%, ± 5% Continuous 0A 5 V @ 1.0 A 12 V @ 0.3A Output Maximum power: Adjustment range: Total regulation: (line and load) Turn-on delay: Transient response: Safety...