Click to expand full text
ENGINEERING DATA SHEET
T441
TIME DELAY RELAY 4 PDT, 10 AMP
APPLICABLE SOCKET: S402
Time delay relay on operate or on release Fixed or adjustable timing delay
Contact arrangement Power supply
4 PDT 28 Vdc
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at Weight Dimensions of case
10 Amps / 28 Vdc < 120 grams 44mm x 39mm x 26mm max
Hermetically sealed corrosion protected metal can (mounting flange tin plated)
CONTACT ELECTRICAL CHARACTERISTICS
Minimum operating cycles
Contact rating per pole and load type
100,000 cycles 20,000 cycles 100,000 cycles 100,000 cycles
on resistive load on inductive load (L/R=5ms) on motor load on lamp load
50 cycles
resistive overload
Load current in Amps @28Vdc
10 8 4 2
40
NUMBERING SYSTEM
T441 - A E - 1001 - B
Basic series designation___