MIL-STD-1275B
MIL-STD-1275B is Elmo Compliance manufactured by Extriq.
..
Elmo pliance with MIL-STD-1275B
February 2007- Ver. 1.0
..
Elmo pliance with MIL-STD-1275B
CHARACTERISTICS OF 28 VOLT DC ELECTRICAL SYSTEMS IN MILITARY VEHICLES
Operating in "battery-powered" applications (with or without an alternator or generator) exposes the electrical equipment to severe electrical interferences such as:
- surges
- spikes
- transients
- EMI
- over voltage
- under voltage
- voltage ripple
- reverse polarity Harsh "battery-powered" environment interferences are unique in nature and have very high energy and long durations. As a result, the "battery-powered" interferences are unable to be managed, resolved or prevented by conventional remedies such as MOVs (metal oxide varistors), tranzorbers, zener and avalanche diodes, passive filters, capacitors, fuses, circuit breakers, etc. which are used to protect electronic equipment. The MIL-STD-1275B sets the requirements that all 24VDC "battery-powered" equipment must be pliant in order to ensure reliable and fault free operation. Although plying with the MIL-STD-1275B is mandatory in military applications, it is highly remended to be adopted in any type of "battery-powered" equipment. The MIL-STD-1275B addresses 3 major interferences: 1. Surge-40V 2. Surge-100V 3. Spike-250V
..
Elmo pliance with MIL-STD-1275B
Surge-40V Electrical System Requirement Equipment shall continue to operate normally throughout these tests without damage to any ponents
Surge 40V
LOCI of SURGES in a FAULT-FREE ELECTRICAL SYSTEM MIL-STD-1275B
40 35
Source Impedance approx. 20 milliohms
P EA K V OL T A GE
30 25 20 18 15 10
1ms
10ms
50ms
100 ms
500ms
1.0 s
..
Elmo pliance with MIL-STD-1275B
Surge-100V Electrical System Requirement Equipment shall function as specified
Surge 100V
LOCI of SURGES in a TYPICAL DC ELECTRICAL SYSTEM
100 90 80...