Click to expand full text
www.DataSheet4U.com
T3/DS3/E3/STS-1
TEW5747 is designed to be used as a receive transformer in the following applications on 75 Ω coaxial lines. • • • – T3/DS3 E3 STS-1 44.736 MBPS 34.368 MBPS 51.84 MBPS
Input Transformer
TEW5747
Approved for use with: SSI 78P2362
Return Loss exceeds the requirements of CCITT G.703.
MECHANICAL 4
0.40
3 Device
0.40
ALL DIMENSIONS ARE IN INCHES
Line 6 1
0.10 DIA O.025
6 5 4
0.30
1 2 3 WHITE DOT GRID 0.10 x 0.10
DRILL O.O40 6 PLACES
ELECTRICAL SPECIFICATION
5550.chp
TEW5747
95/01/13
Line Impedance (Ohms) Turns ratio Inductance (µH) Return Loss Dielectric Strength (Vrms)
(4 - 6) (4 - 6) : (3 - 1) (4 - 6)
75 1:1 > 40 G.703 1500
ISSUE: A
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada.