First Sensor HDI0611AR
Amplified pressure sensors
FEATURES
● 10 mbar to 5 bar, absolute, gage or differential pressure● Digital I2C-bus and analog output
● Precision ASIC signal conditioning
● Calibrated and temperature compensated
● SMT and DIP housings
● RoHS compliant MEDIA COMPATIBILITY To be used with non-corrosive, non-ionic working fluids such as clean dry air, dry gases and the like. SPECIFICATIONS Maximum ratings Supply voltage VS HDI...3 HDI...5 Output current Sink Source 2.7 ... 3.3 VDC 4.5 ... 5.5 VDC max. 6.50 VDC 1 mA 1 mA Lead specifications Average preheating temperature gradient 2.5 K/s Soak time ca. 3 min Time above 217°C 50 s Time above 230°C 40 s Time above 250°C 15 s Peak temperature 260°C Cooling temperature gradient -3.5 K/s Temperature ranges5 Compensated Operating Storage 0 ... +85 °C -20 ... +85 °C -40 ... +125 °C ELECTRICAL CONNECTION 1 2 4 6 3 +Vs Vout SDA SCL GND E / 11650 / G 1/9 HDI