HST-2071DHR - 10/100 BASE-TX TRANSFORMER MODULES

This page provides the datasheet information for the HST-2071DHR, a member of the HST-2071DHR-GROUP 10/100 BASE-TX TRANSFORMER MODULES family.

Features

  • Designed to meet IEEE 802.3 requirements.
  • Primary inductance(Lp)350uH min. @ 100KHz,0.1Vrms,DC 8mA.
  • LL:0.5uH Max @100KHz, 0.1V.
  • Cww:75pF Max@100KHz, 0.1V.
  • Primary DCR:0.9ΩMax;Secondary DCR:1.2ΩMax.
  • Storeage Temperature -25℃ to +125℃.
  • RoHS compliance. Part NO Turn Ratio RX. TX HST-2071DHR 1CT:1CT 1CT:1CT Specifications at 25oC.  Operating temperature 0-70oC Insertion Loss (dB max) 0.1-100MHz Return Loss(dB min . ) MHz 0.5-30 40 50 60-80 DCMR (dB typ. ).

📥 Download Datasheet

Datasheet preview – HST-2071DHR

Datasheet Details

Part number HST-2071DHR
Manufacturer GROUP-TEK
File Size 131.02 KB
Description 10/100 BASE-TX TRANSFORMER MODULES
Datasheet download datasheet HST-2071DHR Datasheet
Additional preview pages of the HST-2071DHR datasheet.
Other Datasheets by GROUP-TEK

Full PDF Text Transcription

Click to expand full text
® A Leading Supplier of Magnetic Components 10/100 BASE MODULES 10/100BASE-TX TRANSFORMER MODULES Features: ● Designed to meet IEEE 802.3 requirements. ● Primary inductance(Lp)350uH min.@ 100KHz,0.1Vrms,DC 8mA . ● LL:0.5uH Max @100KHz, 0.1V ● Cww:75pF Max@100KHz, 0.1V ● Primary DCR:0.9ΩMax;Secondary DCR:1.2ΩMax. ● Storeage Temperature -25℃ to +125℃. ● RoHS compliance. Part NO Turn Ratio RX.TX HST-2071DHR 1CT:1CT 1CT:1CT Specifications at 25oC. Operating temperature 0-70oC Insertion Loss (dB max) 0.1-100MHz Return Loss(dB min .) MHz 0.5-30 40 50 60-80 DCMR (dB typ.) MHz 0.5~100 Crosstalk (dB min .) MHz 0.1~30 60 -1.1 -18 -14.4 -13.1 -12 -30 -40 -35 Isolation Voltage (Vrms) 100 -30 6000VDC 1mA 6S Dimension:mm(inch),Unless otherwise specified , all tolerance are+/-0.25(0.