Click to expand full text
CMA31 Relay
1.COIL DATA 1-1.Nominal Voltage 1-2.Coil Restistance 1-3.Operate Voltage 1-4.Release Voltage 1-5.Coil Power
6~ 24VDC Refer to Coil Data Chart Refer to Coil Data Chart Refer to Coil Data Chart 1600mW
2.CONTACT DATA
2-1.Contact Form
C-1 form C A-1 form A B-1 form B
2-2.Contact Material
Ag Alloy
2-3.Contact Rating
30A 14VDC Resistive (1 Form C)
40A 14VDC Resistive (1 Form A)
30A 14VDC Resistive (1 Form B)
2-4.Max.Switching Voltage
75VDC
2-5.Max.Switching Current
40A
2-6.Max.Switching Power
420W(1 Form C) ,560W(1 Form A)
2-7.Max.Load Current(14VDC Load Voltage)
Load
AB
Max.Carry Current 40A Max.Make Current 100A Max.Break Current 40A
30A 60A 30A
C NO 40A 100A 40A
NC 30A 30A 30A
2-8. Contact Resistance 2-9. Life
Electrical Mechanical
3.GENERAL DATA 3-1.