HRS2H-S-DC5V-T
HRS2H-S-DC5V-T is SIGNAL RELAY manufactured by HKE.
- Part of the HRS2H-S-DC3V-N comparator family.
- Part of the HRS2H-S-DC3V-N comparator family.
HRS2H
SIGNAL RELAY
Safety Approval c
Features
Microminiature relay Dimension: 20.3×9.9×11.4 (mm) High sensitivity 2 Form C contacts
No. E164730 No. 50097843
ORDERING INFORMATION
HRS2H
Enclosure S DC12V T
Coil Voltage
Coil Sensitivity
Blank: 450m W Model T
- High Sensitivity (150m W) S
- Plastic Sealed Type DC3V, DC5V, DC6V DC9V, DC12V, DC24V N
- Sensitivity (200m W) B
- Standard 360m W (48VDC:400m W)
Remarks: 1. Available in 2 Form C only 2. Contact rating: 1A, 2A
SPECIFICATION
CONTACT DATA
Contact Form Contact Material Contact Rating 2 Form C Au Ag overlay, Ag Alloy 1A 120VAC/24VDC 2A 120VAC/24VDC Contact Resistance Max. Switching Voltage Load Max. Switching Current Max. Switching Power Min. Switching Load Life Electrical Mechanical Max. 50mΩ (6VDC 0.1A) 125VAC/30VDC 2A 250VA, 60W 5VDC, 10m A 100,000 operations 15,000,000 operations
GENERAL DATA
Insulation Resistance Dielectric Strength Between open contacts Between coil and contacts Min. 1000MΩ 500VDC 500VAC, 1min 1,000VAC, 1min Max. 7ms Max. 3ms -25℃ to +70℃ 35~95%RH, +40℃ 1,500VAC, 10x160 μs 1,000m/s 100m/s
2 2
Operate Time Release Time Operating Temperature Humidity Surge Strength Endurance Shock Resistance Misoperation
COIL DATA
Nominal Coil Power 150m W, 200m W, 360m W, 450m W
10~55Hz, 1.5mm double amplitude Endurance Vibration Resistance Misoperation 10~55Hz, 1.5mm double amplitude Weight Approximately 5.0g
Note:Data shown are of initial value
SAFETY APPROVAL
File Number UL E164730 TUV 50097843 Contact Form C C C Power Consumption Coil Voltage Contact Rating 1A 120VAC/24VDC 2A 120VAC/24VDC 1A 120VAC/24VDC 1A...