HI-3201 - AVIONICS DATA MANAGEMENT ENGINE

Download the HI-3201 datasheet PDF. This datasheet also covers the HI-3200 variant, as both devices belong to the same avionics data management engine family and are provided as variant models within a single manufacturer datasheet.

General Description

The HI-3200 from Holt Integrated Circuits is a single chip CMOS data management IC capable of managing, storing and forwarding avionics data messages between eight ARINC 429 receive channels, four ARINC 429 transmit channels and a single CAN / ARINC 825 data bus.

Key Features

  • Eight ARINC 429 Receive channels.
  • Four ARINC 429 Transmit channels.
  • CAN Bus / ARINC 825 Interface.
  • 32KB on chip user-configurable data storage memory.
  • Programmable received data filtering for ARINC 429 and CAN buses.
  • Programmable transmission schedulers for periodic ARINC 429 and CAN message broadcasting.
  • Flexible protocol bridge ARINC 429 to CAN and CAN to ARINC 429.
  • SPI Host CPU interface.
  • Auto-initialization feature allows power-on configuration o.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (HI-3200-HOLTIC.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number HI-3201
Manufacturer HOLTIC
File Size 221.00 KB
Description AVIONICS DATA MANAGEMENT ENGINE
Datasheet download datasheet HI-3201 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
October 2016 HI-3200, HI-3201 AVIONICS DATA MANAGEMENT ENGINE / ARINC 429 - CAN BUS BRIDGE GENERAL DESCRIPTION The HI-3200 from Holt Integrated Circuits is a single chip CMOS data management IC capable of managing, storing and forwarding avionics data messages between eight ARINC 429 receive channels, four ARINC 429 transmit channels and a single CAN / ARINC 825 data bus. The ARINC 429 and CAN buses may be operated independently, allowing a host CPU to send and receive data on multiple buses, or the HI-3200 can be programmed to automatically re-format, re-label, re-packetize and retransmit data from ARINC 429 receive buses to ARINC 429 transmit buses, as well as from ARINC 429 to CAN or CAN to ARINC 429.