DESCRIPTION
HP02S is a low power, low voltage device with automatic power down switching. I2C Serial Interface is used for communications with a microprocessor. FEATURES
. 14 Bit ENOB ADC resolution . Supply voltage 2.0v-5.0v . 0° C to + 50° C operating range APPLICATIONS
. Pressure measurement and control systems . Mobile altimeter/barometer systems . Weather forecast products . Adventure or multi-mode watches Block Diagram 1 Free Datasheet Hope RF HP02S BAROMETER MODULE 2011-6-8 Version: 1.4 Pin Name VSS VDD MCLK XCLR SDA SCL Pin Number 1 2 3 4 5 6 Type G P I I I/O I Function power ground power VCC master clock(32k) input ADC reset input (keep low when system is in idle state) . I²C data input and output I2C clock input * XCLR is to reset the AD converter (active low). XCLR should be set to high only during AD conversion phase(reading T1,D1). While at all other states, such as reading calibration factors, this pin should be kept low. ABSOLUTE MAXIMUM RATINGS