Datasheet4U.com

GL7101 Datasheet PDF

HTC KOREA GL7101

The GL7101 is designed for use in earth leakage circuit interrupters for operation directly off the AC line in breakers. It contains pre-regulator, main regulator, after regulator, differential amplifier, level comparator, and latch circuit. The input in the differential amplifier is connected to the secondary node of zero current transformer.
Part No. GL7101
Datasheet GL7101 Download
Manufacturer
HTC KOREA
Description Earth Leakage Current Detector
Buy Stock & Price
GL7101 datasheet page 1 preview

FEATURES

● Low Power Consumption (PD=5mW Typ.)
● Common Built-In Voltage Regulator
● High Gain Differential Amplifier
● High Input Sensitivity
● Minimum External Parts
● Large Surge Margin
● Wide Operating Temperature Range
● High Noise Immunity SOP-8

APPLICATIONS

● High Speed Earth Leakage Circuit Breaker DIP-8 ORDERING INFORMATION Device GL7101SD GL7101SN GL7101 Package SOP-8 DIP-8

DESCRIPTION

The level comparator generates high level when earth leakage current is greater than some level.

ABSOLUTE MAXIMUM RATINGS

(Note 1) CHARACTERISTIC SYMBOL MIN. MAX. UNIT Power Supply Voltage VS - 20 V Power Supply Current IS - 8 mA Storage Temperature Range TSTG −65 150 °C Operating Ambient Temperature Range TA −30 85 °C Note1. Stresses beyond those listed under

ABSOLUTE MAXIMUM RATINGS

may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied.
GL7101 page 2 preview GL7101 page 3 preview