Platinum Resistance Temperature Detector M 620 M series PRTDs are designed for large volume applications where long term stability, interchangeability and accuracy over a large temperature range are vital. Due to the high resistance values of 1000 Ω and 2000 Ω the signal gain is excellent. Typical applications are found in Automotive, White goods, HVAC, Medical and Industrial equipment. Nominal Resistance R0 1000 Ohm at 0° C 2000 Ohm at 0° C Tol erance DIN EN 60751 1996-07 Class B Class B Tolerance DIN EN 60751 2009-05 F 0. 3 F 0. 3 O rder Number Pl astic Bag 32 208 181 32 208 541 The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body.