MAXIMUM RATINGS
Rating CW RF Power Dissipation DC Voltage Between Terminals Storage Temperature Range Operating Temperature Range P VDC Tstg TA HR868.35B Value 0 30 -40 to +85 -10 to +60 Unit dBm V 7-2.Electronic Characteristics Characteristic Center Frequency (+25 ) Insertion Loss Unloaded Q Quality Factor 50 Ω Loaded Q Turnover Temperature Temperature Stability Turnover Frequency Frequency Temperature Coefficient Frequency Aging Absolute Value during the First Year Absolute Frequency Tolerance from 868.350 MHz Sym fC ∆fC IL QU QL T0 f0 FTC |fA| Minimum 868.200 Typical Maximum 868.500 Unit MHz kHz 150 1.7 8,300 1,500 25 fC 0.032 10 1.0 55 2.3 dB kHz ppm/ 2 ppm/yr MΩ DC Insulation Resistance Between Any Two Terminals Motional Resistance RF Equivalent RLC Model Motional Inductance Motional Capacitance Shunt Static Capacitance RM LM CM C0 22 33.5580 1.0021 2.3 2.6 30 Ω µH fF 2.9 pF LCAUTION: Electrostatic Sensitive Device. Observe precautions for handling! C 2003. All Rights Reserved. The center frequency, fC, is measured at the minimum IL point with the resonator in the 50 test system.