HM1500 is a dedicated humidity transducer designed for OEM applications where a reliable and accurate measurement is needed. H October 2001 TECHNICAL 2 DATA MEASUREMENT CONDITIONS G HM1500 is specified for accurate measurements within 10 to 95% RH.
Part No. HM1500
Datasheet HM1500 Download
Manufacturer
Humirel
Description RELATIVE HUMIDITY MODULE
Buy Stock & Price
HM1500 datasheet page 1 preview

FEATURES

G G G G G G G G G Small size Not affected by water immersion Full interchangeability High reliability and long term stability Typical 1 to 4 Volt DC output for 0 to 100 % RH at 5 V DC supply Calibrated within +/- 2 % RH @ 55 % RH Very low temperature dependence Ratiometric to voltage supply within the specified range Suitable for 3 to 7 Volts supply voltage HM 1500 HUMIDITY SENSOR SPECIFIC

FEATURES

G G G G Instantaneous de-saturation after long periods in saturation phase. Patented solid polymer structure. High resistance to chemicals. Fast response time. OPERATING RANGE 100 1 2

MAXIMUM RATINGS

Ratings Symbol Value Unit RELATIVE HUMIDITY IN % INTERMITTENT OPERATION 75 ST EA DY Storage Temperature Supply Voltage (Peak) Humidity Operating Range Tstg Vs RH -30 to 70 7 0 to 100 -30 to 60 °C Vdc % RH °C 50 E AT ST 25 Temperature Operating Range Ta Peak conditions : less than 10% of the operational time. 0 -40 -20 0 20 40 60 80 AMBIENT TEMPERATURE IN °C CHARACTERISTICS Characteristics (Ta = 23°C, Vs = 5Vdc, RL > 1MΩ otherwise stated) Symbol Min.