HY29LV160BF-70
FEATURES n Single Power Supply Operation
- Read, program and erase operations from 2.7 to 3.6 volts
- Ideal for battery-powered applications High Performance
- 70, 80, 90 and 120 ns access time versions Ultra-low Power Consumption (Typical Values At 5 Mhz)
- Automatic sleep mode current: 1 µA
- Standby mode current: 1 µA
- Read current: 9 m A
- Program/erase current: 20 m A Flexible Sector Architecture:
- One 16 KB, two 8 KB, one 32 KB and thirty-one 64 KB sectors in byte mode
- One 8 KW, two 4 KW, one 16 KW and thirty-one 32 KW sectors in word mode
- Top or bottom boot block configurations available Sector Protection
- Allows locking of a sector or sectors to prevent program or erase operations within that sector
- Sectors lockable in-system or via programming equipment
- Temporary Sector Unprotect allows changes in locked sectors (requires high voltage on RESET# pin) Fast Program and Erase Times
- Sector erase time: 0.25 sec typical for each sector
- Chip erase time: 8 sec typical
-...