ICS SF0300BA01973S
Filter
300 MHz Filter Part Number SF0300BA01973S Micro Networks Corp., 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, TYPICAL PERFORMANCE Horizontal: 2 MHz/div Vertical (from top): 10 dB/div 1 dB/div 200 ns/div SPECIFICATION NOTE – All electrical specifications apply at room temperature (23 °C) only. PARAMETER Center Frequency (FC) 1 Insertion Loss 2 3dB Bandwidth 3 4 40dB Bandwidth 3 4 Ultimate rejection at FC +/-(6 to 40) MHz 4 Average Passband Delay Passband Amplitude Ripple 3 5 Passband Group Delay Ripple 3 6 Passband Phase Linearity 3 6 Return Loss at Input and Output 3 6 Triple Transit Suppression Source and Load Impedance Frequency change with Temperature (TC ≈ 20 °C) Operating Temperature Range Storage Temperature Range Notes: 1. 2. 3. 4. 5. 6. Min 299.935 3.2 45 Typ 300.010 15 3.3 4.6 50 1.67 0.75 70 3 46 50 -0.009(T-TC)2 Max 300.085 19 4.7 1.8 1.0 200 10 10 40 -30 -40 +70 +85 Units MHz dB MHz MHz dB µs dB p-p ns p-p deg p-p dB dB Ω kHz / °C2 °C °C Center frequency is defined as the mean of the upper and lower 3dB points.