DESCRIPTION
/FEATURES
Typical applications are in input rectification and these products are designed to be used with International Rectifier Switches and Output Rectifiers which are available in identical package outlines. Fully isolated package (VINS = 2500 VRMS ). UL E78996 approved VF < 1.1V @ 10A IFSM = 200A VRRM 800 to 1600V Output Current in Typical APPLICATIONS
APPLICATIONS
Capacitive input filter TA = 55°C, TJ = 125°C common heatsink of 1°C/ W Single-phase Bridge 12.0 Three-phase Bridge 16.0 Units A Major Ratings and Characteristics Characteristics IF(AV) Sinusoidal waveform VRRM IFSM VF TJ @ 10 A, TJ = 25°C Package Outline 10ETS..FP Units 10 800 to 1600 200 1.1 - 40 to 150 A V A V °C TO-220AC FULLPAK 1 10ETS..FP SAFEIR Series Preliminary Data Sheet I2142 rev. A 03/99 Voltage Ratings Part Number VRRM , maximum peak reverse voltage V 10ETS08FP 10ETS12FP 10ETS16FP 800 1200 1600 VRSM , maximum non repetitive peak reverse voltage V 900 1300 1700 I RRM 150°C mA 0.5 Provide terminal coating for voltages above 1200V ABSOLUTE MAXIMUM RATINGS
Parameters IF(AV) Max.