DESCRIPTION
/FEATURES
Typical applications are in input rectification and these products are designed to be used with International Rectifier Switches and Output Rectifiers which are available in identical package outlines. VF < 1V @ 5A IFSM = 200A VRRM 800 to 1200V Output Current in Typical APPLICATIONS
APPLICATIONS
NEMA FR-4 or G10 glass fabric-based epoxy with 4 oz (140µm) copper Aluminum IMS, RthCA = 15°C/W Aluminum IMS with heatsink, RthCA = 5°C/W TA = 55°C, TJ = 125°C, footprint 300mm2 Single-phase Bridge 1.2 2.5 5.5 Three-phase Bridge 1.6 2.8 6.5 Units A Major Ratings and Characteristics Characteristics IF(AV) Sinusoidal waveform VRRM Range (*) IFSM VF TJ @ 5A, TJ = 25°C Package Outline Units A V A V °C 8EWS..S 8 800 to 1200 200 1.0 - 55 to 150 TO-252AA (D-Pak) (*) for higher voltage up to 1600V contact factory 1 8EWS..S SAFEIR Series Bulletin I2108 rev. G 08/00 Voltage Ratings VRRM, maximum Part Number peak reverse voltage V 8EWS08S 8EWS10S 8EWS12S 800 1000 1200 VRSM , maximum non repetitive peak reverse voltage V 900 1100 1300 IRRM 150°C mA 0.5 ABSOLUTE MAXIMUM RATINGS
Parameters IF(AV) Max.