FEATURES
High voltage Electrically isolated base plate 3000 V RMS isolating voltage Industrial standard package Simplified mechanical designs, rapid assembly High surge capability Large creepage distances UL E78996 approved MAGN-A-pak Power Modules 170A 230A 250A DESCRIPTION
They can be interconnected to form single phase or three phase bridges or as AC-switches when modules are connected in anti-parallel mode. These modules are intended for general purpose applications such as battery chargers, welders and plating equipment and where high voltage and high current are required (motor drives, U.P.S., etc.). Major Ratings and Characteristics Parameters IT(AV) @ 85°C IT(RMS) ITSM I t 2 IRK.170.. 170 377 IRK.230.. IRK.250.. Units 230 510 7500 7850 280 256 2800 250 555 8500 8900 361 330 3610 A A A A KA2s KA2s KA2√s V o @ 50Hz @ 60Hz @ 50Hz @ 60Hz 5100 5350 131 119 1310 I √t VDRM / VRRM TJ range 2 Up to1600 Up to 2000 Up to1600 -40 to 130 C 1 IRK.170, .230, .250 Series Bulletin I27102 rev.