INTEGRATED CIRCUITS DIVISION
Parameter Blocking Voltage Load Current On-Resistance (max)
Rating 230 450 4
Units
VP mADC/mArms
Features
• Integrated Active Current-Limit Protection • Thermal Shutdown • High Surge Capability • Linear AC or DC Operation • Low Power Consumption • Clean, Bounce-free Switching • Low Power Drive Requirements
Applications
• Instrumentation • Elevator Load Control • Fire Panels • Security (alarms, horns, buzzers) • Industrial Controls • Medical Equipment • Peripherals
Approvals
• UL 508 Certified Component: File E69938
Block Diagram
2 LED +
1 LED -
Gate Driver
Thermal Shutdown
Current Limit
Control
3 AC/DC Load
CPC1511
Single-Pole, Normally Open Relay
with Thermal Shutdown & Current Limiting
Description
CPC1511 is a single-pole, normally open (1-Form-