Click to expand full text
INTEGRATED CIRCUITS DIVISION
Parameter Load Voltage Load Current On-Resistance (max) Input Control Current
Rating 600 ±120 35 2
Units
VP mA
mA
Features
• Integrated Active Current-Limit with Over-Voltage Protection
• Thermal Regulation • 600VP Blocking Voltage • Guaranteed Turn-On: 2mA Input Control Current • 3750Vrms Input/Output Isolation • Low Drive Power Requirements • Arc-Free With No Snubbing Circuits • No EMI/RFI Generation • Flammability Rating UL 94 V-0
Applications
• In-Rush Current Control • Heating, Ventilation, Air Conditioning Control (HVAC) • Security Systems • Power Supplies • Home Appliances • IC Equipment Protection • Instrumentation • Medical Equipment—Patient/Equipment Isolation • Aerospace • Industrial Controls
Block Diagram
LOAD
Gate Drive Control
+ Current Li