IXYS XW180GA34B
Water Cooled Heatsink
Water Cooled Heatsink Type XW180GA34# Date: - 1st June, 2017 Data Sheet Issue: - 2 Water Cooled Heatsink Type XW180GA34# Characteristics – Double side cooling, 2 coolers + 1 Semiconductor PARAMETER Rth (C/W) Cooler-input water thermal resistance Rth (C/W) Cooler-input water thermal resistance TYP. TEST CONDITIONS 3 6l/m flow rate, Power – 2.5kW 2.3 10l/m flow rate, Power – 2.5kW Characteristics – Double side cooling, 3 coolers + 2 Semiconductors UNITS K/kW K/kW PARAMETER Rth (C/W) Cooler-input water thermal resistance Rth (C/W) Cooler-input water thermal resistance Physical/Electrical properties TYP. TEST CONDITIONS 3.8 6l/m flow rate, Power – 2.5kW 2.7 10l/m flow rate, Power – 2.5kW UNITS K/kW K/kW PARAMETER P Pressure difference between input and output water per cooler P Pressure difference between input and output water per cooler M Mass without busbar (XW180GC34A) M Mass with busbar (XW180GC34B) Dimensions MIN. TYP. MAX. TEST CONDITIONS UNITS - 63 - 6l/m kPa - 140 - 10l/m kPa -...