Key Features
- ESD / transient protection according to: - IEC61000-4-2 (ESD): ±14 kV (air) / ±11 kV (contact) - IEC61000-4-4 (EFT): ±1 kV / ±20 A (5/50 ns) - IEC61000-4-5 (Surge): ±2 A (8/20 μs)
- Bi-directional maximum working voltage: VWM = ±5.5 V
- Line capacitance: CL = 0.12 pF (typical) at f = 2.5 GHz
- Clamping voltage: Vcl = 30 V (typical) at ITLP = 16 A with Rdyn = 1.29 Ω
- Very low leakage current: IL <1 nA (typical)
- Small form factor SMD size 0201, low profile (0.58 x 0.28 x 0.15 mm³) Potential applications
- Super high speed interface
- RF antenna Product validation Qualified for industrial applications according to the relevant tests of JEDEC47/20/22. Device information YAC YAC