Description
P G-TS (S)LP -2_Dual_Diode_S erie_P inConf_and_S c hematic Diag.
Features
- ESD/Transient/Surge protection of one data / Vbus line exceeding standard:.
- IEC61000-4-2 (ESD): ±30 kV (air/contact discharge).
- IEC61000-4-4 (EFT): ±50 A (5/50 ns).
- IEC61000-4-5 (surge): ±5 A (8/20 μs).
- Bi-directional symmetrical working voltage: VRWM = ±13.2 V.
- Low capacitance: CL = 6 pF (typ. ).
- Very low ESD clamping voltage, very low dynamic resistance: RDYN = 0.29 Ω (typ. ).
- Pb-free (RoHS compliant) and halogen free packa.