• Part: IDT49C466
  • Manufacturer: Integrated Device
  • Size: 234.25 KB
Download IDT49C466 Datasheet PDF
IDT49C466 page 2
Page 2
IDT49C466 page 3
Page 3

IDT49C466 Description

The IDT49C466/A 64-bit Flow-thruEDC is a high-speed error detection and correction unit that ensures data integrity in memory systems. The flow-thru architecture, with separate system and memory data buses, is ideally suited for pipelined memory systems. Implementing a modified Hamming code, the IDT49C466/A corrects all single bit hard and soft errors, and detects all double bit errors.

IDT49C466 Key Features

  • 64-bit wide Flow-thruEDC™
  • Separate System and Memory Data Input/Output Buses
  • Error Detect Time: 10ns
  • Error Correct Time: 15ns
  • Corrects all single bit errors; Detects all double bit errors and some multiple bit errors
  • Configurable 16-deep bus read/write FIFOs with flags
  • Simultaneous check bit generation and correction of memory data
  • Supports partial word writes on byte boundaries
  • Low noise output
  • Sophisticated error diagnostics and error logging