HA1-5320-2 Datasheet 1 Microsecond Precision Sample and Hold Amplifier

Manufacturer: Intersil (now Renesas)

Overview

HA-5320 Data Sheet April 1999 File Number 2857.4 1 Microsecond Precision Sample and Hold Amplifier The HA-5320 was designed for use in precision, high speed data acquisition systems.

The circuit consists of an input transconductance amplifier capable of providing large amounts of charging current, a low leakage analog switch, and an output integrating amplifier.

The analog switch sees virtual ground as its load; therefore, charge injection on the hold capacitor is constant over the entire input/output voltage range.

Key Features

  • Gain, DC.
  • . . . . 2 x 106 V/V.
  • Acquisition Time.
  • . 1.0µs (0.01%).
  • Droop Rate.
  • . . 0.08µV/µs (25oC) 17µV/µs (Full Temperature).
  • Aperture Time.
  • . . . . 25ns.
  • Hold Step Error (See Glossary).
  • . . 5mV.
  • Internal Hold Capacitor.
  • Fully Differential Input.