Datasheet4U.com

HI-549 Datasheet PDF

Intersil HI-549

the HI-549 is a 4-Channel differential device. For further information see Application Notes AN520 and AN521. For MIL-STD-883 compliant parts, request the HI-546/883, HI-547/883, HI-548/883 and HI-549/883 datasheets.
Part No. HI-549
Datasheet HI-549 Download
Manufacturer
Intersil
Description CMOS Analog MUX
Buy Stock & Price
HI-549 datasheet page 1 preview

FEATURES

● Analog Overvoltage Protection. . . . . . . . . . . . . . . . . . 70VP-P
● No Channel Interaction During Overvoltage
● Guaranteed rON Matching
● Maximum Power Supply . . . . . . . . . . . . . . . . . . . . . . 44V
● Break-Before-Make Switching
● Analog Signal Range . . . . . . . . . . . . . . . . . . . . . . . . 15V
● Access Time (Typical) . . . . . . . . . . . . . . . . . . . . . . . 500ns
● Standby Power (Typical) . . . . . . . . . . . . . . . . . . . . 7.5mW
● Pb-Free Plus Anneal Available (RoHS Compliant)

APPLICATIONS

● Data Acquisition
● Industrial Controls
● Telemetry FN3150 Rev 7.00 Jun 15, 2016 Page 1 of 25 HI-546, HI-547, HI-548, HI-549 Ordering Information PART NUMBER TEMP. PART MARKING RANGE (oC) PACKAGE PKG. DWG. # HI1-0546-2 HI1-546-2 -55 to 125 28 Ld CERDIP F28.6 HI3-0546-5Z (Note) (No longer available, recommended replacement: HI9P0546-9Z, HI4P0546-5Z) HI3-546-5Z 0 to 75 28 Ld PDIP* (Pb-free) E28.6 HI4P0546-5Z (Note) HI4P546-5Z 0 to 75 28 Ld PLCC (Pb-free) N28...