• Part: HS-26C32RH-T
  • Manufacturer: Intersil
  • Size: 139.59 KB
Download HS-26C32RH-T Datasheet PDF
HS-26C32RH-T page 2
Page 2
HS-26C32RH-T page 3
Page 3

HS-26C32RH-T Description

® Data Sheet HS-26C32RH-T August 1, 2008 FN4592.2 Radiation Hardened Quad Differential Line Receiver Intersil’s Satellite Applications Flow™ (SAF) devices are fully tested and guaranteed to 100kRAD total dose. These QML Class T devices are processed to a standard flow intended to meet the cost and shorter lead-time needs of large volume satellite manufacturers, while maintaining a high level of reliability. The...

HS-26C32RH-T Key Features

  • QML Class T, Per MIL-PRF-38535
  • Radiation Performance
  • Gamma Dose
  • 1 x 105 RAD(Si)
  • SEU and SEL
  • Immune to 100MeV/mg/cm2
  • EIA RS-422 patible Inputs
  • CMOS patible Enable Inputs
  • Input Fail Safe Circuitry
  • High Impedance Inputs when Disabled or Powered Down