Datasheet Summary
®
Data Sheet June 2, 2006 FN8141.1
Precision 5.0V FGA™ Voltage Reference
Features
- Output Voltage: 5.000V
- Absolute Initial Accuracy = ±0.5mV
- Ultra Low Power Supply Current: 500nA
- Low Temperature Coefficient = 3ppm/°C
- 10mA Source & Sink Current Capability
- 10ppm/1000hrs Long Term Stability
- Very Low Dropout Voltage: 100mV @ no load
- Supply Voltage Range: 5.1V to 9.0V
- 5kV ESD (Human Body Model)
- Standard Package: 8 Ld SOIC
- Temp Range: -40°C to +85°C
- Pb-Free Plus Anneal Available (RoHS pliant) APPLICATIONS
- High Resolution A/Ds & D/As
- Digital Meters
..
DESCRIPTION The X60008-50 FGA™ voltage references are very high precision analog...