KK7101
KK7101 is GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR manufactured by Kodenshi AUK Group.
Description
The KK7101N/D is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre regulator, main regulator, after regulator, differential amplifier, level parator, latch circuit. The input in the differential amp latch circuit. The input in the differential amplifier is connect to the secondary node of zero current transformer. The level parator generates high level when earth leakage current is greater than some level.
Feature
- Low Power Consumption (PD=5m W) 100V/200V
- 100V/200V mon Built-in Voltage Regulator
- High Gain Differential Amplifier
- High Input Sensitivity
- Minimum External Parts
- Large Surge Margin
- Wide Operating Temperature Range (TА= -40 to 85°C)
- High Noise Immunity
- Meet U. L. 943 standards
ORDERING INFORMATION KK7101N Plastic KK7101D SOIC KK7101S SIP-8 TA = -40° to 85° C for all packages.
Absolute Maximum Ratings
- Supply Voltage
- Supply Current ..
- Power Dissipation
- Operating Temperature
- Storage Temperature
20V 8m A 200m W
- 40 to 85°C
- 55 to 125°C
Pin Configuration (Top View)
Block Diagram
..
Remended Operating Condition: TA=-30°C to 80°C
PARAMETER Supply Voltage Vs-GND Capacitor OS-GND Capacitor SYMBOL V+ Cvs Cos MIN. 12 1 TYP. MAX UNIT V µF µF
Electrical Characteristics
PARAMETER
SYMBOL
CONDTIONS V+=12V, VR
- VI = 30 m V V+ = 16V, VR
- VI = X V+ = 16 V, VR
- VI = 30 m V VOD = 1.2 V V+ = 16 V, VR
- VI = short VOD = 0.8 V l SI = 580µA VSC = 1.4 V l SI = 530µA VOS = 0.8 V l SI = 480µA V+ = 16 V V+ = l2V V+ = 12 V, VOSL = 0.2 V V+ = 12 V, IIC = 20 m A IIDC = 100m A ISM = 7 m A VOS = 0.5 V, VR
- VI = X V+ = 16 V, VR
- VI = 0.3 V
Supply Current 1
- Trip Voltage Differential Amplifier Output Current 1 Differential Amplifier Output current 2 Output...