APR-B10
Features
- VFD and SCR waveforms current measurement
- True RMS output
- Split core type
- 5V & 10V switch selectable voltage output.
- DIN mounting & Panel mounting
- Eliminates insertion loss
- Switch selectable ranges
APR 50 B10 APR 100 B10 APR 200 B10 APR 400 B10 ≥ 10 kΩ +24 ±5% V DC 5 k V 18 V
Load resistance Supply voltage R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn Limitation of voltage output
Advantages
- Large aperture for cable up to Ø18mm
Accuracy-Dynamic performance data
- High isolation between primary and secondary circuits < ±1 % of IPN < ±0.5 % of IPN < ±0.5 % of IPN ±1 m V/K ±0.1 %/K < 1000 ms 10 .. 6000 Hz
- Easy to mount
ε
VOE VOT TC ε G tr f
Accuracy @ IPN, TA = 25°C (without offset) Linearity (0 .. ± IPN) Electrical offset voltage, TA = 25°C Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth (-3 d B)
Applications
- VFD Controlled Loads: VFD output indicates how the motor and attached load...