FHSAH600 Overview
1 Uref Reference voltage 2 Uout Output voltage 3 GND Ground terminal 4 UC Supply voltage 5 NC Not connected or GND 6 7 8 Polarity OCDE OCDI UE OCD External OCD Internal OCD External OCD threshold voltRaEgreef terminal RE B Uout − Uref is positive following the direction of the arrow. Uref UE OCD Uout OCDI Cref Cout GND OCDE UC NC Table 2: Ideally, RE ref + RE should have a value around 200 kΩ due to current...
FHSAH600 Key Features
- Hall effect current sensor with Integrated Magnetic Concentrator (IMC)
- Magnetic field measurement range ±3.3 mT
- Supply voltage 5 V
- Low power consumption
- Operating temperature range: -40 ... 125 °C
- High bandwidth: 160 kHz
- Excellent linearity < 0.5 % Full Scale
- Sensitivity error < 1 % from -40 ... 125 °C
- Insulated current measurement
- Small footprint with standard SOIC8 surface mount PCB