Datasheet4U Logo Datasheet4U.com

HAIS100-P - Current Transducer

Key Features

  • 100 ±300 HAIS 100-P/100-TP 1) 150 ±450 HAIS 150-P/150-TP 1) 200 ±600 HAIS 200-P 400 ±600 HAIS 400-P GTh Theorical sensitivity @ IPN Vout Analog output voltage @ IP Vref Reference voltage 2) Output voltage Output impedance 0.625 V/ IPN VOE +(0.625.
  • IP/ IPN) V 2.5 ±0.025 V typ. 200 Ω Load impedance ≥200 kΩ RL Load resistance Rout Output internal resistance CL Capacitive loading (±20 %) UC Supply voltage (±5 %) 3) IC Current consumption @ U.

📥 Download Datasheet

Datasheet Details

Part number HAIS100-P
Manufacturer LEM
File Size 424.05 KB
Description Current Transducer
Datasheet download datasheet HAIS100-P Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer HAIS 50 .. 400-P HAIS 50 .. 150-TP For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IPN = 50 .. 400 A IPN = 50 .. 150 A Electrical data All data are given with RL = 10 kΩ Primary nominal Primary current Type rms current IPN (A) measuring range IPM (A) 50 ±150 HAIS 50-P/50-TP 1) Features 100 ±300 HAIS 100-P/100-TP 1) 150 ±450 HAIS 150-P/150-TP 1) 200 ±600 HAIS 200-P 400 ±600 HAIS 400-P GTh Theorical sensitivity @ IPN Vout Analog output voltage @ IP Vref Reference voltage 2) Output voltage Output impedance 0.625 V/ IPN VOE +(0.625·IP/ IPN) V 2.5 ±0.025 V typ.