LEM HAIS50-P
Current Transducer
FEATURES
100 ±300 HAIS 100-P/100-TP 1) 150 ±450 HAIS 150-P/150-TP 1) 200 ±600 HAIS 200-P 400 ±600 HAIS 400-P GTh Theorical sensitivity @ IPN Vout Analog output voltage @ IP Vref Reference voltage 2) Output voltage Output impedance 0.625 V/ IPN VOE +(0.625●IP/ IPN) V 2.5 ±0.025 V typ. 200 Ω Load impedance ≥200 kΩ RL Load resistance Rout Output internal resistance CL Capacitive loading (±20 %) UC Supply voltage (±5 %) 3) IC Current consumption @ UC = 5 V ≥2 kΩ <5 Ω 4.7 nF 5 V <19 mA●● Hall effect measuring principle
●● Galvanic separation between primary and secondary circuit
●● Insulation test voltage 2500 V
●● Low power consumption
●● Single power supply +5 V
●● Fixed offset & sensitivity
●● Insulating plastic case recognized according to UL 94-V0. Advantages
●● Small size and space saving
●● Only one design for wide current ratings range Accuracy - Dynamic performance data