FEATURES

● Hall effect measuring principle
● Galvanic isolation between primary
●
●
●
● and secondary circuit Isolation voltage 3000 V Low power consumption Extended measuring range( 3 x IPN) Insulated plastic case recognized according to UL 94-V0 VC IC R IS VOUT ROUT RL Supply voltage (± 5 %) 4) Current consumption Isolation resistance @ 500 VDC Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance Load resistance ± 15 ± 15 > 1000 ±4 100 > 10 V mA MΩ V Ω kΩ Advantages
● Easy mounting
● Small size and space saving
● Only one design for wide current ratings range Accuracy-Dynamic performance data ε X L VOE VOH VOT TCε G tr f Accuracy @ IPN, TA = 25°C (without offset) Linearity error 1) (0 .. ± IPN) Electrical offset voltage, TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth 2) (- 3 dB) < ± 1 % of IPN < ± 1 % of IPN < ± 20 mV < ± 10 mV <±1 mV/K < ± 0.1 %/K <5 µs DC ..
HAT600-S page 2 preview HAT600-S page 3 preview