Key Features

  • 1200 A ±3600 A ±15 V ±15 mA 30000 At.
  • Hall effect measuring principle.
  • Insulating plastic case recognized according to UL 94-V0. Advantages > 1000 ±4 100 > 1 MΩ V.
  • Low insertion losses Ω.
  • Easy installation kΩ.
  • Low power consumption.
  • Small size and space saving You understand that the information contained in these files may not be adequate, complete or accurate, and the products depicted in drawings, mode.

📥 Download Datasheet

Datasheet Details

Part number HAX1200-S
Manufacturer LEM
File Size 611.05 KB
Description Current Transducer
Datasheet download datasheet HAX1200-S Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer HAX 1200-S For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IP N = 1200 A 3D CAD Model HAX 1200-S 17 December 2015 YNS Electrical data IP N Primary nominal RMS current IP M Primary current, measuring range 1) UC Supply voltage (±5 %) 1) IC Current consumption ÎP Overload capability RINS Insulation resistance @ 500 V DC Uout Output voltage (Analog) @ ±IP N, RL = 10 kΩ, TA = 25 °C Rout Output internal resistance appr. RL Load resistance Accuracy - Dynamic performance data ε Error @ IP N, TA = 25 °C (excluding offset) 2) εL Linearity error (0 ...