LEM HNC-200P
Current Transducer HNC- 200~300P
FEATURES
● Hall effect measuring principle● Galvanic isolation between primary
● Isolation voltage 2500 V
● Low power consumption and secondary circuit Supply voltage (± 5 %) ± 15 Current consumpution 15 + ISN R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn 2.5 Accuracy-Dynamic performance data Advantages < ± 1 % of IPN < 0.25 % of IPN ± 0.5 mA ± 0.3 mA ± 0.005mA/K°C <1 µs ± 0.04 %/°C ε X L IO IHC IOT tr TCε G Accuracy @ T A = 25°C Linearity (0 .. ± IPN ) Electrical offset current @IP = 0, @T A = 25°C Hysteresis offset current @ IP = 0, after an excursion of IPN 0°C .. +70°C Thermal drift of IO Response time @ 90% of IP Thermal drift of the gain (% of reading)
● Easy mounting
● Small size and space saving
● Only one design for wide current
● High immunity to external interference ratings range
APPLICATIONS
● DC motor drives● Switched Mode Power Supplies General data TA TS RS m Ambient operating temperature Ambient storage temperature HNC - 200P
● AC variable speed drives
● Uninte...