  • Panel mount type R. m. s. voltage for AC isolation test, 50/60Hz, 1 min 2.0 Accuracy-Dynamic performance data X Advantages < ±1 % of IPN mA mA ε IO Accuracy @ T A = 25°C L Linearity (0 . . ± IPN ) Electrical offset current @IP = 0, @T A = 25°C Hysteresis offset current @ IP = 0, after an excursion of IPN Thermal drift of IO Response time @ 90% of IP Thermal drift of the gain (% of reading) 0°C . . +70°C < ± 0.5 % of IPN ± 0.5 ± 0.6 IHC IOT.

📥 Download Datasheet

Datasheet Details

Part number HNC-40CA
Manufacturer LEM
File Size 125.65 KB
Description Current Transducer HNC-40CA
Datasheet download datasheet HNC-40CA Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer HNC-40CA For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 400 A Electrical data IPN IP RM ISN KN VC IC Vd Primary nominal DC or rms current Primary current, measuring range Measuing resistance Second nominal current Turns ratio Supply voltage (± 5 %) Current consumpution 400 0 .. ± 800 20 100 1 : 4000 ± 15 20 + ISN V mA kV A A Ω mA Features • Hall effect measuring principle • Panel mount type R.m.s. voltage for AC isolation test, 50/60Hz, 1 min 2.0 Accuracy-Dynamic performance data X Advantages < ±1 % of IPN mA mA ε IO Accuracy @ T A = 25°C L Linearity (0 ..